直流偏磁对变压器电流影响及其抑制研究

来源:电工电气发布时间:2020-04-20 14:20浏览次数:799
直流偏磁对变压器电流影响及其抑制研究
 
高歌,徐建源,曹辰
(沈阳工业大学 电气工程学院,辽宁 沈阳 110870)
 
摘 要:以SZ11-100000/220 变压器为研究对象,应用PSCAD/EMTDC搭建变压器模型进行时域仿真,分析不同直流偏置量下变压器励磁电流及谐波特性的影响规律。基于阻容隔直法抑制措施进行优化分析,提出一种具有故障保护作用的阻容隔直法抑制措施。通过设计电路主要参数,搭建变压器模型,仿真分析直流偏磁抑制措施使用前后的变压器直流偏磁情况。仿真结果表明,变压器励磁电流畸变程度与流入中性点的直流量呈正相关。当直流分量为5 A时,励磁电流正半周为6.23 A,负半周为-0.30 A,并出现偶次谐波。当采取所提出的抑制措施后,中性点的直流量控制在了可允许范围内,极大地减弱了直流偏磁程度,若系统故障,装置中旁路立即接地,保护了电容器安全运行。
关键词:变压器;直流偏磁;阻容隔直法;励磁电流;谐波特性;抑制措施
中图分类号:TM401+.1 文献标识码:A 文章编号:1007-3175(2020)04-0011-05
 
Research on the Influence of Transformer Current and Its Suppression Under DC Bias
 
GAO Ge, XU Jian-yuan, CAO Chen
(School of Electrical Engineering, Shenyang University of Technology, Shenyang 11 0870, China)
 
    Abstract: Taking SZ11 -100000/220 transformers as the research object, PSCAD/EMTDC was used to build the transformer model for time domain simulation. The influences of transformer excitation current and harmonic characteristics under different DC offsets are analyzed. Based on the optimization analysis of resistive-capacitor DC-blocking method, a resistive-capacitor DC-blocking method with fault protection is proposed. By devising the main parameters of the circuit, a transformer model is built, and the DC bias of the transformer before and after the DC bias suppression measures are simulated and analyzed. The simulation results show that the degree of distortion of the transformer's excitation current is positively related to the direct current flowing into the neutral point.When the DC component is 5 A, the positive half cycle of the excitation current is 6.23 A, the negative half cycle is -0.30 A, and even harmonics appear.When the proposed suppression measures are taken, the DC value of the neutral point is controlled within the allowable range, which greatly reduces the degree of DC bias.If the system fails, the bypass in the device is immediately grounded to protect the capacitor's safe operation.
    Key words: transformer; DC bias; resistive-capacitor DC-blocking method; excitation current; harmonic characteristics; suppression measures
 
参考文献
[1] 杜建平,李书连,栾兰,等.直流偏磁下400 kV单相电力变压器励磁特性的试验研究[J]. 变压器,2017,54(1):50-53. 
[2] 林湘宁,杨国稳,翁利琍,等.直流偏磁下变压器无功消耗增多对系统电压的影响分析[J]. 高电压技术,2016,42(1):272-278. 
[3] 肖华.特高压直流输电引起的变压器直流偏磁问题的研究[D]. 成都:西南交通大学,2010. 
[4] 李晓萍,文习山,陈慈萱.单相变压器直流偏磁励磁电流仿真分析[J]. 高电压技术,2005,31(9):8-10.
[5] 骆志坚,叶杰宏.直流单极运行时谐波对并联电容器的影响[J]. 电力电容器与无功补偿,2009,30(5):58-61. 
[6] KAPPENMAN J G, NORR S R, SWEEZY G A, et al. GIC mitigation:A neutral blocking/bypass device to prevent the flow of GIC in power systems[J]. IEEE Transactions on Power Delivery,1991,6(3):1271-1281.
[7] ZHU H, OVERBYE T J. Blocking Device Placement for Mitigating the Effects of Geomagnetically Induced Currents[J].IEEE Transactions on Power Systems,2015,30(4):2081-2089.
[8] ETEMADI A H, REZAEI-ZARE A. Optimal Placement of GIC Blocking Devices for Geomagnetic Disturbance Mitigation[J].IEEE Transactions on Power Systems,2014,29(6):2753-2762.
[9] 刘春明,黄彩臣,林晨翔.抑制变压器地磁感应电流的电容隔直装置安装位置优化[J]. 电力系统自动化,2016,40(16):132-137. 
[10] 杨培宏,郑许朋,刘连光,等.变压器中性点配置小电阻器对治理电网GIC的效果分析[J]. 电网技术,2017,41(4):1324-1331. 
[11] BOLDUC L, GRANGER M, PAREG, et al. Development of a DC Current-Blocking Device for Transformer Neutrals[J].IEEE Transactions on Power Delivery,2005,20(1):163-168.
[12] 潘卓洪,梅桂华,张露,等.抑制变压器直流偏磁的电流注入法[J].  电力系统自动化,2009,33(20):88-91. 
[13] 梅桂华,梁文进,刘艳村,等.变压器直流偏磁电流阻容抑制装置的开发应用[J]. 高电压技术,2009,35(10):2581-2585. 
[14] 李长云.半岛地质环境下直流偏磁效应计算与评估研究[D]. 济南:山东大学,2011 .