Suzhou Electric Appliance Research Institute
期刊号: CN32-1800/TM| ISSN1007-3175

SUBSCRIPTION MANAGEMENT

发行征订

首页 >> 发行征订 >> 征订方式

密封油内渗导致的转子匝间绝缘劣化诊断

来源:电工电气发布时间:2024-02-01 08:01浏览次数:88

密封油内渗导致的转子匝间绝缘劣化诊断

冯宇哲1,潘建伟2,王新3,杨立川1
(1 国网浙江省电力有限公司电力科学研究院,浙江 杭州 310014;
2 浙江浙能台州第二发电有限责任公司,浙江 台州 318016;
3 浙江浙能技术研究院有限公司,浙江 杭州 311121)
 
    摘 要:密封油内渗导致转子匝间绝缘劣化,是转子匝间短路故障的主要原因之一。某台 1 050 MW 汽轮发电机在运行状态和极间电压试验均无异常的情况下,通过分析重复脉冲试验结果,判断转子绕组已存在由密封油内渗导致的转子匝间绝缘劣化问题;拔出转子护环,发现转子端部绕组区域存在大量密封油内渗现象,同时转子匝间绝缘未发生金属性短路;对匝间绝缘劣化的机理进行了阐述并给出了检修策略,以避免类似问题的再次发生。
    关键词: 发电机;转子绕组;密封油内渗;匝间绝缘劣化
    中图分类号:TM311     文献标识码:B     文章编号:1007-3175(2024)01-0055-04
 
Diagnosis of Rotor Interturn Insulation Deterioration
Caused by Seal Oil Infiltration
 
FENG Yu -zhe1, PAN Jian-wei2, WANG Xin3, YANG Li-chuan1
(1 State Grid Zhejiang Electric Power Co., Ltd. Electric Power Research Institute, Hangzhou 310014, China;
2 Zhejiang Zheneng Taizhou Second Electric Power Generation Co., Ltd, Taizhou 318016, China;
3 Zhejiang Zheneng Technology Research Institute Co., Ltd, Hangzhou 311121, China)
 
    Abstract: The sealing oil internal leakage leads to the degradation of generator rotor inter-turn insulation, which is one of the main reasons for rotor inter-turn short circuit faults. In this paper, a 1 050 MW steam turbine generator is taken as an example, and there is no abnormality in its operating state and interpolar voltage test, it was judged that the rotor winding had multi-point inter-turn insulation deterioration caused by sealing oil infiltration by analyzing the results of repeated pulse tests. When the rotor retainer ring was pulled out, it found that there was a large amount of sealing oil infiltration in the winding area at the end of the rotor, and there was no metallic short circuit in the insulation between the rotor turns; the mechanism of inter turn insulation degradation was explained and maintenance strategies were provided to avoid similar problems from happening again.
    Key words: generator; rotor winding; seal oil infiltration; interturn insulation deterioration
 
参考文献
[1] 牟春华,居文平,黄嘉驷,等. 火电机组灵活性运行技术综述与展望[J]. 热力发电,2018,47(5) :1-7.
[2] 薛信春.600 MW 发电机转子匝间短路的分析与处理[J]. 华东电力,2001,29(8) :28-29.
[3] 冯宇哲,罗统领,金泱,等. 一起 RSO 检测无效的大型隐极同步电机转子动态匝间短路故障检测与处理[J]. 大电机技术,2023(2) :30-34.
[4] 郗常骥. 汽轮发电机故障实例与分析[M]. 北京:中国电力出版社,2002.
[5] 关建军. 大型汽轮发电机转子绕组匝间短路故障的诊断研究[J]. 大电机技术,2003(2) :18-22.
[6] 冯宇哲,李卫军,杨立川.660 MW 发电机转子绕组匝间短路故障检测与处理[J]. 电工电气,2023(7) :46-50.
[7] 李永刚,李和明,赵华. 汽轮发电机转子绕组匝间短路故障诊断新判据[J] . 中国电机工程学报,2003,23(6) :112-116.
[8] 李晓明,刘东明. 大型汽轮发电机转子绕组匝间短路故障的测试与分析[J]. 大电机技术,2003(3) :7-11.
[9] 凌霜寒,黄立军,米贤才,等. 基于重复脉冲法的转子绕组匝间短路故障诊断[J] . 浙江电力,2016,35(8) :42-45.
[10] ALBRIGHT D R.Interturn Short-Circuit Detector for Turbine Generator Rotor Windings[J].IEEE Transactions on Power Apparatus and Systems,1971,PAS-90(2) :478-483.
[11] 中国电力企业联合会. 隐极同步发电机转子匝间短路故障诊断导则:DL/T 1525—2016[S]. 北京:中国电力出版社,2016 :4-6.
[12] 中国机械工业联合会. 隐极式同步发电机转子匝间短路测定方法:JB/T 8446—2013[S]. 北京:机械工业出版社,2013 :3-8.
[13] 冯宇哲,孙海军,柯元丰,等. 发电机氢气纯度偏低的治理和典型氢气提纯装置的应用[J] . 电工电气,2021(7) :39-43.