一种用于高压电缆试验的引线架设装置的研制

来源:电工电气发布时间:2018-02-13 09:13 浏览次数:573
一种用于高压电缆试验的引线架设装置的研制
 
韩宇泽,周平,姚天翼
(国网南京供电公司, 江苏 南京 210019)
 
    摘 要:为解决户内电缆终端因引线通道安全距离不足造成的无法开展耐压试验的问题,设计了一种应用于室内有窗变电站中户内电缆终端开展高压电缆交流耐压试验的引线架设装置。该装置采用基于绝缘隔离管的设计方案,从线芯导体、绝缘材料、绝缘表面结构及可调支架四部分进行了模块设计,经在多条110 kV电缆线路交流耐压试验中现场应用,解决了户内电缆终端耐压试验引线通道紧张,无法实现被试终端与试验设备安全相连的问题。
    关键词:高压电缆;室内变电站;户内电缆终端;交流耐压试验;引线架设装置
    中图分类号:TM247     文献标识码:B     文章编号:1007-3175(2018)02-0059-04
 
A Kind of Development of Lead Wire Erecting Device for High Voltage Cable Test
 
HAN Yu-ze, ZHOU Ping, YAO Tian-yi
(State Grid Nanjing Power Supply Company, Nanjing 210019, China)
 
    Abstract: In order to solve the problem unable to carry out secure connection tests caused by indoor cable terminal test lead channel tension, this paper design a set of high voltage cable test wire erection device used for inside cable terminal of indoor transformer substation with windows to carry out high voltage cable alternating current (AC) voltage withstand test. This device adopted the design scheme based on insulated isolation tubal. The module was designed in four parts including cable core conductor, insulating material, insulating surface structure and adjustable support. After the application of field verification of AC voltage withstand tests in multi-110 kV cable circuits, there is no tension for the indoor cable on the terminal voltage test of substation leads channel. The tested terminal realizes the safety connection with the testing equipment.
    Key words: high voltage cable; indoor transformer substation; inside cable terminal; alternating current voltage withstand test; lead wire erecting device
 
参考文献
[1] 姚翔,王颂虞,李世毅,等. 交联电缆现场变频耐压辅助试验系统[J]. 电力设备,2006,7(7):62-65.
[2] 王一波. 基于现场交接试验的高压电缆交流耐压及局放技术应用研究[D]. 保定:华北电力大学,2014.
[3] 郭忠敏,韩兴国. 高压设备( 电缆、GIS) 特殊试验技术[J]. 四川水力发电,2016,35(2):1.
[4] 郑瑞强.110 kV电缆工频耐压试验装置的应用——无裸露引出端的高压电缆耐压试验装置的应用[J].中国科技博览,2016(6):310-311.
[5] 韩宇泽,储强,周平,等. 封闭式变电站中高压电缆交流耐压同步局放测量的试验引线系统研究[J].电线电缆,2017(2):41-46.
[6] 汤铭辉. 高压电缆现场交流耐压试验简析[J]. 河南科技,2013(6):109.