模拟量输入合并单元计量性能检测研究

来源:电工电气发布时间:2021-11-19 08:19 浏览次数:385

模拟量输入合并单元计量性能检测研究

梁凯1,张博2,朱慧1
(1 国网江苏省电力有限公司无锡供电分公司,江苏 无锡 214002;
2 国网江苏省电力有限公司徐州供电分公司,江苏 徐州 221006)
 
    摘 要:针对模拟量输入合并单元计量误差特性及相关测试项目,研究了检测装置的技术方案。提出了基于时钟同步法的信号生成技术,降低了相位噪声;采用自适应直流供电系统和热保护技术,增强装置可靠性;构建了基于 NI PCI-4472 的合并单元校验系统,满足 0.2 级及以下等级合并单元测试。对三个厂家的合并单元进行了测试,结果表明,所测合并单元的部分计量性能需要提高才能确保电能计量准确。研究结果可推进相关标准制定,有利于提升数字化电能计量系统的可靠性和准确度,促进智能电网建设。
    关键词:智能变电站;数字化电能计量系统;模拟量输入合并单元;计量性能检测装置
    中图分类号:TM933.4     文献标识码:A     文章编号:1007-3175(2021)11-0051-04
 
Research on Metering Performance Testing of Analog-Input Merging Unit
 
LIANG Kai1, ZHANG Bo2, ZHU Hui1
(1 Wuxi Power Supply Company of State Grid Jiangsu Electric Power Co., Ltd, Wuxi 214002, China;
2 Xuzhou Power Supply Company of State Grid Jiangsu Electric Power Co., Ltd, Xuzhou 221006, China)
 
    Abstract: This paper examined the technical solution for detection devices for the measurement error characteristics of the analog-input merging unit and related test items. It proposed a signal generation technology based on the clock synchronization method to reduce phase noise.It used an adaptive DC power supply system and thermal protection technology to enhance the device’s reliability. It also constructed a merging unit verification system based on NI PCI-4472 to meet the merging unit test of level 0.2 and below. By testing the combined units of the three manufacturers, the results showed that part of the measurement performance of the tested combined units needs to be improved to ensure the accuracy of electric energy measurement. The research result can promote the formulation of relevant standards, which is conducive to improving the reliability and accuracy of the digital electric energy measurement system and promoting the construction of smart grids.
    Key words: intelligent substation; digital electric energy metering system; analog-input merging unit; metering performance detection device
 
参考文献
[1] 蒋博,徐文志,杨坤,等. 智能变电站过程层采样数据组网传输分析[J] . 电工电气,2012(5) :16-20.
[2] 程含渺,夏国芳,梁凯. 一起数字化电能计量系统故障现场排查[J]. 电工电气,2018(2) :42-44.
[3] 陈霞君,刘少凡,张济韬,等. 现代电能计量系统综述[J]. 电工电气,2015(1) :1-4.
[4] 朱贺,丁泉,程成,等. 智能变电站合并单元应用现状与展望[J]. 电工电气,2015(6) :5-9.
[5] 张博君.DDS 任意波形发生器研究[J]. 现代电子技术,2012,35(14) :100-102.
[6] 李志坚,曾大治,龙腾.DDS 相位截断杂散分析[J].信号处理,2009,25(11) :1706-1709.
[7] 王建新,刘国岁,朱伟强. 一种 DDS/PLL 混合型高分辨率频率合成器[J] . 电子测量与仪器学报,1999,13(4) :72-75.
[8] 金数波,邓贤进,王豪才. 相位舍入对直接数字频率合成杂散特性的影响[J] . 系统工程与电子技术,2002,24(10) :16-18.