    摘 要:针对现有直流、交流激励式电缆振荡波局部放电(局放)检测系统在成本投入、检测准确性方面存在的问题,研究了一种基于串联谐振试验系统的交流激励式新型电缆振荡波局放检测系统。对现有串联谐振试验设备进行改造,在励磁变高压端并联大功率高压固态电子开关并与变频电源一体化封装;通过变频电源主机控制电子开关闭合,使被试电缆、谐振电抗器、回路电阻形成阻尼振荡,激发电缆潜在缺陷产生局放;通过专用分压器实现电缆本体电压监测并采集局放信号至专用分析终端。实测结果表明,新型振荡波局放检测系统采用交流电压激励,不会造成电缆绝缘电荷积聚,能在完成交流耐压试验的同时进行振荡波局放检测,并有效发现电缆潜在缺陷。
    关键词: 电缆;串联谐振系统;交流激励;振荡波;局部放电
    中图分类号:TM855     文献标识码:B     文章编号:1007-3175(2022)06-0048-05
 
Research on the Partial Discharge Detection System of AC Excitation
Oscillating Wave of the Cable Based on the Series Resonance System
 
WU Hong, HAO Jin-peng, WANG Bo, YANG Kai, FANG Zi-yi, NIU Bo
(Power Research Institute of State Grid Ningxia Electric Power Co., Ltd, Yinchuan 750011, China)
 
    Abstract: The DC/AC excitation of the oscillating wave of the cable of the partial discharge detection system has problems with cost input and examination accuracy. This paper studied an AC excitation of the oscillating wave of the cable of the partial discharge detection system based on the series resonance system.It reformed the series resonant testing equipment. The end of the HV excitation paralleled the solid-state switch with high voltage and high power and integrated and packaged with the frequency converter.The tested cable, resonance reactor, and circuit resistance formed damped oscillation when the main engine controlled switch of the frequency converter closed, stimulating the potential defects of the cable and producing partial discharge.This paper realized the voltage monitoring of the cable by using a special voltage divider. In addition, it collected the partial discharge signals and sent the signals to the special analysis terminal.The results show that the new oscillation wave partial discharge detection system would not cause the accumulation of insulative electric charge of the cable by using AC voltage excitation. It could complete AC withstand voltage test while conducting the oscillating wave partial discharge detection, and discover the potential defects of the cable.
    Key words: cable; series resonance system; AC excitation; oscillation wave; partial discharge
 
参考文献
[1] 国家电网有限公司. 配电电缆线路试验规程:Q/GDW 11838—2018[S] . 北京:中国电力出版社,2019 :5-9.
[2] 庞圣养. 交联聚乙烯电缆局放检测技术综述[J] .电力安全技术,2021,23(10) :17-21.
[3] 曾泽宇,段建家,段肖力,等. 电力电缆振荡波局部放电检测应用[J] . 湖南电力,2020,40(5) :39-42.
[4] 张龙,黄亭,李洪杰. 振荡波电压下 XLPE 电缆局部放电定位和智能识别的研究[J] . 供用电,2020,37(12) :81-86.
[5] ZHU G , ZHOU K , ZHAO S , et al . A Novel Oscillation Wave Test System for Partial Discharge Detection in XLPE Cable Lines [J].IEEE Transactions on Power Delivery,2020,35(4) :1678-1684.
[6] 王伟,蒋达,董文妍,等. 电缆振荡波试验中直流充电速率对 XLPE 中空间电荷积聚的影响[J]. 高电压技术,2018,44(9) :2881-2888.
[7] 陈玉豪,刘宜成,刘力,等. 基于电容串联式的新型振荡波测试系统的研究[J] . 电测与仪表,2020,57(14) :88-92.
[8] 李婧,黄晨曦,郭金明,等.30 kV 阻尼交流振荡波测试系统用新型电力电子开关的研制[J] . 电气技术,2015(12) :42-46.
[9] 郭小凯,卢雨欣,孙廷玺,等. 用于电缆局部放电检测的储能式交流激励型振荡波测试系统[J] . 西安交通大学学报,2020,54(10) :100-107.
[10] 王庆华,卢雨欣,沈谢林,等.10 kV 电缆测试用 DC/AC 充电型振荡波系统研究[J]. 电力电子技术,2021,55(6) :52-55.
[11] 李巍巍,白欢,吴惟庆,等. 基于振荡波局部放电检测的电力电缆绝缘老化状态评价与故障定位[J].电测与仪表,2021,58(9) :147-151.
[12] 中国电力企业联合会.6 kV~35 kV 电缆振荡波局部放电测量系统:DL/T 1575—2016[S] . 北京:中国电力出版社,2016 :2-3.