一起高压断路器弹簧机构拒分故障分析
杨镇宁,庞博,何溪康,张鹏
(许继德理施尔电气有限公司,河南 许昌 461000)
摘 要:高压断路器是电力系统中常用的控制和保护设备,以 12 kV 断路器开关柜弹簧机构拒分故障为背景,分别对断路器核心模块的分闸阻力矩和机构分闸输出扭矩进行测试,验证机构与开关模块的适配能力。检查机构核心部件分闸掣子的尺寸,通过计算摩擦圆半径以及驱动力臂,查明故障原因是分闸掣子与限位块导致力臂变短,阻力增加造成闭锁,分闸弹簧无法驱动滚子实现分闸。
关键词: 高压断路器;分闸掣子;机构拒分;摩擦圆半径
中图分类号:TM561 文献标识码:B 文章编号:1007-3175(2023)05-0040-04
Analysis of a Mechanism Refuse Operation Failure of the
High Voltage Circuit Breaker Spring
YANG Zhen-ning, PANG Bo, HE Xi-kang, ZHANG Peng
(XJ Delishier Electric Co., Ltd, Xuchang 461000, China)
Abstract: The high voltage circuit breaker is the common control and protection equipment used in power systems. The paper, taking the mechanism refuse operation failure ccurring to the 12 kV circuit breaker switchgear as the research object, tests the opening resistance torque and output torque of the circuit breaker core module respectively to verify the mechanism adaptability to the switching module. Through checking the opening switch size of the mechanism core component and calculating friction circle radius and driving arms, it finds that the cause of this failure is the opening switch and the limit block make arms shorter and the increase of resistance leads to closedown so that the opening spring cannot drive the roller to open.
Key words: high voltage circuit breaker; opening switch; mechanism refuse operation; friction circle radius
参考文献
[1] 于冉冉,余砾,王建华,等. 利用合闸复位时间差提高高压断路器弹簧操动机构合闸锁扣可靠性[J].高压电器,2010,46(6):40-44.
[2] 豆龙江. 断路器弹簧操作机构故障机理分析及诊断方法研究[D]. 北京:华北电力大学,2019.
[3] 王栋,谢伟,付海金,等. 一起 500 kV SF6 断路器爆炸故障事故的分析[J] . 高压电器,2015,51(9):177-181.
[4] 杨秋玉,彭彦卿,庄志坚. 基于 ADAMS 的高压断路器弹簧机构动力学仿真与故障分析[J] . 高压电器,2018,54(6):67-73.
[5] 石峰,王淼,叶德武,等. 一起分闸掣子缺陷引起的断路器合后即分故障分析[J] . 电气应用,2020,39(10):89-94.
[6] 何贤盛. 四辊轧机辊系稳定性的有限元模拟和实验研究[D]. 秦皇岛:燕山大学,2021.
[7] 张翱. 润滑减摩涂层的制备及摩擦磨损性能研究[D].济南:山东大学,2020.