摘 要: 及时掌握绝缘子表面污秽程度并采取措施能有效减少污闪事故的发生。介绍了泄漏电流法、等值盐密法、表面污层电导率法、污闪电压梯度法和脉冲电流法的电量监测方法以及微波辐射法、声发射监测法和红外成像监测法的非电量监测方法,并对它们的优缺点进行了分析。绝缘子发生污闪是温度、湿度、运行电压等多因素综合的结果,指出绝缘子污秽度监测研究方向,应建立多因素、多参量的综合性的监测方法。
关键词: 绝缘子;污秽;电量监测方法;非电量监测方法
中图分类号:TM216 文献标识码:A 文章编号:1007-3175(2014)09-0009-03


Research on Filth Insulator Monitoring Method 

CAI Sheng-zhou1, WANG Deng-ju2, CHEN Ren-jun2, TAN Xiao-long2 
(1 Panzhihua Power Supply Company, Sichuan Electric Power Company, Panzhihua 617000, China;
2 Ertan Hydropower Plant, Yalong River Hydropower Development Co., Ltd, Panzhihua 617000, China)
 
 

Abstract: Timely detection of insulator surface filth degree and timely measures can reduce the accidents of pollution flashover. Introduction was made to the electric quantity monitoring methods including leakage current method, equivalent salt density method, surface filth layer conductivity method, pollution flashover voltage gradient method and pulse current method, together with the non-electric quantity monitoring methods such as microwave radiation method, acoustic emission monitoring method and infrared imaging monitoring method, and analysis was made to their advantages and disadvantages. Insulators turned up pollution flashover because of temperature,humidity, operational voltage etc synthetical factors. It is pointed out that the monitoring research direction of insulator filth degree should build up synthetic monitoring methods of comprehensive factors and parameters.
         Key words: insulator; filth; electric quantity monitoring method; non-electric quantity monitoring method


参考文献
[1] 宿志一.雾霾天气对输变电设备外绝缘的影响[J].电网技术,2013,37(8):2284-2290.
[2] 何松.四川电网防污闪技术对策分析[J].四川电力技术,2010,33(6):63-66.
[3] 宿志一,李庆峰.我国电网防污闪措施的回顾和总结[J].电网技术,2010,34(12):124-130.
[4] 何艳娇,张仲秋,马丽山,等.某110 kV输电线路污闪原因分析[J].电瓷避雷器,2011(6):50-52.
[5] 关志成,刘瑛岩,周远翔,等.绝缘子及输变电设备外绝缘[M].北京:清华大学出版社,2006.
[6] 李波,刘念,李瑞叶.变电站绝缘子污秽在线监测技术[J].高电压技术,2008,34(6):1288-1291.
[7] 黄敬尧,孙明浩,汪芳宗,等. 基于微波辐射原理的污秽绝缘子检测仪研制[J]. 电测与仪表,2011,48(6):67-70.
[8] 林秀钦,赵全香,吴沃生,等. 基于微波辐射探测技术的绝缘子污秽检测试验[J]. 广东电力,2013,26(7):74-77.
[9] 高强,魏星,崔鹏程.声发射技术在绝缘子污秽放电监测中的应用[J].高压电器,2006,42(1):60-62.
[10] 李自品,舒乃秋,李红玲,等. 绝缘子污秽放电的声发射核主成分诊断法[J]. 高电压技术,2012,38(11):3008-3014.
[11] 李佐胜,李文利,姚建刚,等.应用绝缘子红外热像处理的现场污秽等级检测方法[J].中国电机工程学报,2010,30(4):132-138.
[12] 何洪英,杨迎建,姚建刚,等.利用红外热像检测高压绝缘子污秽度的影响因素研究[J].高电压技术, 2010,36(7):1730-1736.