    摘 要:针对传统单一接地故障选线装置的选线效果不理想,分析了智能变电站小电流接地故障选线系统发展趋势,并提出了一种新的小电流接地故障选线系统。该系统结合智能变电站的组成结构和数据传输特点,由间隔层保护测控装置完成对线路信号的采集,利用GOOSE 报文传输机制通过站控层网络,上送故障选线装置,由该装置进行故障判断。仿真结果表明该系统可快速、准确地判断出故障线路。
    关键词:小电流接地故障选线;GOOSE 传输机制;仿真测试;准确性
    中图分类号:TM862     文献标识码:B     文章编号:1007-3175(2017)06-0048-03
 
Application of GOOSE Transmission Mechanism in Small Current Grounding Fault Line Selection System
 
PAN Liang-yu, AI Shao-wei, XIE Hai-biao
(XJ Electric Co., Ltd, Xuchang 461000, China)
 
    Abstract: Aiming at the unsatisfactory route selection result of traditional single grounding fault line selection device, this paper analyzed the development trend of small current grounding fault line selection system in intelligent substation and proposed a new kind of small current grounding fault line selection system. This system combined the intelligent substation composition structure with data transmission characteristics and finished the line signal acquisition through the interlayer protection device. By using the GOOSE message transmission mechanism through the station control layer network, the line signal was sent to the fault line selection device for fault judgment. The simulation results show that this system can judge the fault line quickly and correctly.
    Key words: small current grounding fault line selection; GOOSE transmission mechanism; simulation test; accuracy
 
参考文献
[1] 薛永端,冯祖仁,徐丙垠,等. 基于暂态零序电流比较的小电流接地选线研究[J]. 电力系统自动化,2003,27(9):48-53.
[2] 张矿,许小兵,李建敏,等. 小电流接地选线功能在智能变电站的应用[J]. 电工技术,2014(11):1-3.
[3] 范建忠,马千里.GOOSE通信与应用[J]. 电力系统自动化,2007,31(19):85-90.
[4] 孙军平,盛万兴,王孙安. 新一代变电站自动化网络通信系统研究[J]. 中国电机工程学报,2003,23(3):16-19.
[5] 徐丙垠,薛永端,李天友,等. 小电流接地故障选线技术综述[J]. 电力设备,2005,6(4):1-7.
[6] 陈志亮,范春菊. 基于5次谐波突变量的小电流接地系统选线[J]. 电力系统及其自动化学报,2006,18(5):37-41.
[7] 齐郑,郭锐,杨以涵. 基于数字化变电站的小电流接地故障选线实现方案[J]. 电力系统自动化,2009,33(24):54-57.
[8] 陈奎. 单相接地故障综合判据选线研究[D]. 徐州:中国矿业大学,2005.
[9] 闫静,金黎,张志成,等. 小电流接地选线系统的设计与实现[J]. 高电压技术,2003,29(12):12-14.